CDM-840 Remote Router Revision 2
Serial-based Remote Product Management MN-CDM840
7–23
Parameter
Type
(Instruction
Code
Arguments for
Command or
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 and 57)
Command
(Target to
(Instruction
Code &
Response to Query
(Target to Controller)
Unit Name
Sets or returns the SNMP System Name string
Example: <1/SSN=Remote1.
Note: If not configured it returns empty string
SSN!
(see Description of
Arguments)
Number
Returns the 9-digit serial number.
(see Description of
Arguments)
for Internal
10MHz High-
stability
Reference
Sets or returns the fine adjustment of the Internal 10MHz Reference on the
High-Stability Frequency Reference module in the form sddd, where:
s= sign [– (negative) or + (positive)]
ddd= value, 0-999.
ADJ?
ADJ*
ADJ#
(see Description of
Arguments)
String
Sets or returns the user-defined Circuit ID string, which is 4 to 32 characters in
length. Valid characters include:
Space ( ) * + – , . / 0 9 and A thru Z
Example: <1/CID=RxCircuitID’cr’
CID?
CID*
CID#
(see Description of
Arguments)
Mode
Sets or returns Unit Test Mode in the form x, where:
0=Normal Mode (no test)
1=Tx CW
2=Tx Alternating 1,0 Pattern
3 = QPSK PN Pattern
TST?
TST*
TST#
(see Description of
Arguments)
Sets or returns the IP address and network prefix for the 10/100 BaseT
Ethernet Traffic port, in the form xxx.xxx.xxx.xxx/yy, where:
xxx.xxx.xxx.xxx is the IP address, and
yy is the network prefix (8-30)
Example: <1/IG1=192.168.001.004/24’cr’
IG1?
IG1*
IG1#
IG1= xx.xxx.xxx.xxx/yy (See
description of arguments)