CDM-840 Remote Router Revision 2
Serial-based Remote Product Management MN-CDM840
7–18
7.3.8 LNB (Low-Noise Block Downconverter) Parameters Commands and Queries
Parameter
Type
(Instruction
Code
Arguments for
Command or
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 and 57)
Command
(Target to
(Instruction
Code &
Response to Query
(Target to Controller)
High
Limit
Sets or returns the current high limit value in the form xxx, where:
xxx = current high limit value from 0 to 500 mA.
Example: <1/LNH=123’cr’
LNH?
LNH*
LNH#
(see Description of
Arguments)
Low
Limit
Sets or returns the current low limit value in the form xxx, where:
xxx = current low limit value from 0 to 500 mA.
LNL?
LNL *
LNL #
(see Description of
Arguments)
Reference
Enable
Sets or returns the LNB Reference Enable in the form x, where:
0=Disable
1=Enable
LNR?
LNR*
LNR#
(see Description of
Arguments)
Power
Control
Sets or returns the LNB DC Power Supply Control in the form x, where:
0 = Off
1 = 13V LNB Voltage
2 = 18V LNB Voltage
3 = 24V LNB Voltage
Example: <1/LPS=3’cr’
LPS?
LPS*
LPS#
(see Description of
Arguments)
Voltage
Returns the LNB voltage value in volts
(see Description of
Arguments)
Returns ther LNB current value in mA.
(see Description of
Arguments)