Comtech-ef-data MCED-100 User Manual Page 41

  • Download
  • Add to my manuals
  • Print
  • Page
    / 96
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 40
MCED-100 MetaCarrier Embedding Device Revision 1
Rear Panel Connectors and Pinouts MN-MCED100
3–5
3.3 IF Connections
THERE MAY BE DC VOLTAGES PRESENT ON THE TYPE ‘N’ TX IF CONNECTORS, UP
TOA MAXIMUM OF 48VOLTS,IF THEUPLINK MODEMHAS BUCPOWER SUPPLY
OUTPUT.
3.3.1 Tx (OUT) Connectors
3.3.2 Rx (IN) Connectors
Rx(OUT)LBandConnector Notes:
1. ReturnlossontheLBandportsistypically betterthan14dB.
2. If connection to an LBand 75Ω system is require d, a Type ‘N’ to Type ‘F’ adapter can be
usedandisavailablefromComtechEFDataasanoptionalacces
sory.Whileareductionin
returnlosswilloccurwhenadaptingfrom50Ωto75Ωoperation,theeffectinmostsystems
willbeimperceptible.
3.4 GPS INPUT Connections
TheMCED100providesuserstheabilitytoinsertGPSlocationdataintotheCarrierIDmessage
string.TheGPSlocationdataisformattedintheGLL(Geograp hicPositionLatitude/Longitude)
subsetoftheNMEA0183Protocol.ThisdatacanbegeneratedeitherbytheMCED100internal
GPSreceiver(usinganexternalactiveGPSantenna),anexternalGPSuni
t(connectedviaEIA
232),orbymanualusercontrol.
ItisrecommendedthatoutputbytheexternalGPSofanymessagesotherthan
NMEA0183Protocolstandar dmessagesbedisabled.
Tx Connector Name Connector Type Description Direction
Tx (OUT) | 70-140MHz BNC 75 Female Tx IF Signal, 70/140 MHz
Out
Tx (OUT) | L-BAND Type ‘N’ 50 Female Tx IF Signal, L-Band
Rx Connector Name Connector Type Description Direction
Rx (IN) | L-BAND Type ‘N’ 50 Female Rx IF Signal, L-Band
In
Rx (IN) | 70-140 MHz BNC 75 Female Rx IF Signal, 70/140 MHz
Page view 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 95 96