Comtech EF Data SDM-650B Specifications Page 159

  • Download
  • Add to my manuals
  • Print
  • Page
    / 434
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 158
SDM-300L3 Satellite Modem Revision 0
Front Panel Operation MN/SDM300L3.IOM
4–63
FUNCTION SELECT: FAULTS/ALARMS: OUTDOOR UNIT
OUTDOOR UNIT
-----
Note: Faults are only displayed if active.
Fault Active - When:
Current Displays a current fault. ODU (BUC) Power is On and Low or/High Current Alarm set.
Voltage Displays a voltage fault. ODU (BUC) Power is On and ODU Voltage deviates more than
20% from nominal.
Temperature Displays a temperature fault. ODU (BUC) Power is On and FSK is ON.
PLL Lock Displays PLL Lock fault. ODU (BUC) Power is On and FSK is ON.
Checksum Displays checksum fault. ODU (BUC) Power is On and FSK is ON.
Page view 158
1 2 ... 154 155 156 157 158 159 160 161 162 163 164 ... 433 434

Comments to this Manuals

No comments