SDM-300L3 Satellite Modem Revision 0
Front Panel Operation MN/SDM300L3.IOM
4–15
FUNCTION SELECT: CONFIGURATION: MODULATOR:
ODU OUTPUT DELAY
ODU OUTPUT DELAY
00.00 MIN SEC
Programs the ODU Output delay with 0.0 to 20.00 minutes. At power up, the M&C delays
carrier turn On by the programmed time. During output delay timeout, the front panel
carrier On LED flashes and the ODU output delay screen shows the remaining delay time.
Normally, when using this feature, the ODU 10MHz reference is On and the ODU Power
Supply is On. This allows the ODU or BUC time to warm-up before the carrier is
transmitted. Upon entry, the current status of the ODU Output Delay is displayed. Press []
or [] to make the selection. Press <ENTER> to execute the change.
FUNCTION SELECT: CONFIGURATION: MODULATOR:
ODU 10 MHZ REF
ODU 10 MHz REF
OFF
Programs the ODU 10 MHz REF On or Off. The reference is transmitted up the center
conductor of the TX-IF connector.
Upon entry, the current status of the ODU 10 MHz REF is displayed. Press [] or [] to
make the selection. Press <ENTER> to execute the change.