SDM-309B Satellite Modem Remote Control
MN/U-SDM309B Rev. # B-Bβ25
INS_xxxβcrβ Insert (OK/FLT)
BWA_xxxβcrβ Receive Backward Alarm (OK/FLT)
BER_xxxβcrβ Frame BER (OK/FLT)
RXD_xxxβcrβ Receive Data Loss/AIS (OK/FLT)
OVFL_xxxβcrβ Buffer Overflow (OK/FLT)
UNFL_xxxβcrββlfβ] Buffer Underflow (OK/FLT)
5.17 Bulk Consolidated Status
This command causes bulk modem status to be returned. To reduce the length of the
response, message parameter data are returned without identifiers. However, parameter
identification can be determined by order of return. Each status parameter is terminated
with a β,β (comma) except for the last parameter which has the standard message
termination sequence (βcrββlfβ]). The maximum number of characters returned is
approxamately 230. Most of the data returned is formated the same way as the single
command status request (refer to the appropriate portions of this document in preceeding
Sections).
Command: <add/BCS_βcrβ
Response: >add/BCS_p1,p2,p3, . . . pnβcrββlfβ]
Where βpnβ is the last parameter returned.
Parameter 1 (p1): Modulator RF output ON/OFF.
p1 = n, where βnβ is β0β to indicate off or β1β to indicate on.
Parameter 2 (p2): Modulator IF frequency.
p2 = nnn.nnnn, where βnnn.nnnnβ is the modulator IF frequency in MHz.
Parameter 3 (p3): Modulator output power level.
p3 = snn.n, where βsnn.nβ transmitter power output power level in dBm.
Parameter 4 (p4): Modulator rate currently programmed.
p4 = nnn_mmmm.m, where βnnnβ is the code rate and βmmmm.mβ is the data rate in Kbps.
Parameter 5 (p5): Modulator filter A assignment.
p5 = nnn_mmmm.m, where βnnnβ is the code rate and βmmmm.mβ is the data rate in Kbps.
Parameter 6 (p6): Modulator filter B assignment.
p6 = nnn_mmmm.m, where βnnnβ is the code rate and βmmmm.mβ is the data rate in Kbps.
Parameter 7 (p7): Modulator filter C assignment.
p7 = nnn_mmmm.m, where βnnnβ is the code rate and βmmmm.mβ is the data rate in Kbps.
Parameter 8 (p8): Modulator filter D assignment.
p8 = nnn_mmmm.m, where βnnnβ is the code rate and βmmmm.mβ is the data rate in Kbps.
Parameter 9 (p9): Carrier only mode ON/OFF.
p9 = n, where βnβ is β0β to indicate off or β1β to indicate on.
Parameter 10 (p10): Differential encoder enable ON/OFF.
p10 = n, where βnβ is β0β to indicate off or β1β to indicate on.
Parameter 11 (p11): Demodulator IF frequency.
p11 = nnn.nnnn, where βnnn.nnnnβ is the demodulator IF frequency in MHz.
Parameter 12 (p12): Demodulator rate currently programmed.
p12 = nnn_mmmm.m, where βnnnβ is the code rate and βmmmm.mβ is the data rate in Kbps.
Parameter 13 (p13): Demodulator filter A assignment.
p13 = nnn_mmmm.m, where βnnnβ is the code rate and βmmmm.mβ is the data rate in Kbps.
Parameter 14 (p14): Demodulator filter B assignment.
p14 = nnn_mmmm.m, where βnnnβ is the code rate and βmmmm.mβ is the data rate in Kbps.
Parameter 15 (p15): Demodulator filter C assignment.
p15 = nnn_mmmm.m, where βnnnβ is the code rate and βmmmm.mβ is the data rate in Kbps.
Parameter 16 (p16): Demodulator filter D assignment.
p16 = nnn_mmmm.m, where βnnnβ is the code rate and βmmmm.mβ is the data rate in Kbps.