Ku-Band Satellite Transceiver Revision 9
Terminal Mode Commands MN/KST2000AB.IOM
B–9
System
Maintenance
Status
Command
Response
<add/MS_’cr’
>add/MS_’cr’
UCT_nn’cr’
HPT_nn’cr’
DCT_nn’cr’
MCT_nn’cr’
PRF_nn’cr’
FTD_xxx’cr’
HV_xxx’cr’’lf’]
Where: nn = UC Temperature in °C
nn = HPA Temperature in °C
nn = DC Temperature in °C
nn = M&C Temperature in °C
nn = Comtech EF Data HPA corrected RF
output power
N/A = OEM SSPA
N/A = OEM TWTA
xxx = (OK/DLY or N/A) OEM TWTA only,
Heater timer complete
xxx = ON/OFF or N/A OEM TWTA only,
high voltage status
Up Converter
Current Faults
Command
Response
<add/US_’cr’
>add/US_’cr’
RF_xxx’cr’
UC_xxx’cr’
SSYN_xxx’cr’
KSYN_xxx’cr’
LSSYN_xxx’cr’
LKSYN_xxx’cr’
PROG_xxx’cr’
SFLT_#’cr’’lf’]
RF Output (ON/OFF) Actual Status
Up Converter Module (OK/FLT)
S-Band Synthesizer Lock Detect (OK/FLT)
Ku-Band Synthesizer Lock Detect (OK/FLT)
Latched S-Band Synthesizer Lock Detect (OK/FLT)
Latched Ku-Band Synthesizer Lock Detect (OK/FLT)
Inter-processor Communications (OK/FLT)
Number of stored faults (# = 1 to 10)
HP Current Faults
2 and 4 Watt
SSPAs
Current Faults
(Comtech EF
Data)
Command
Response
<add/HS_’cr’
>add/HS_’cr’
RF_xxx’cr’
HPA_xxx’cr’
BV1_xxx’cr’
+9.75V_xxx’cr’
-5V_xxx’cr’
PROG_xxx’cr’
SFLT_#’cr’’lf’]
RF Output (ON/OFF) Actual Status
HPA Converter Module (OK/FLT)
Bias Voltage #1 (OK/FLT)
+9.75 V Power Supply (OK/FLT)
–5 Volt Power Supply (OK/FLT)
Inter-processor Communications (OK/FLT)
Number of stored faults (# = 1 to 10)
HP Current Faults
8 Watt SSPAs
Current Faults
(Comtech EF
Data)
Command
Response
<add/HS_’cr’
>add/HS_’cr’
RF_xxx’cr’
HPA_xxx’cr’
BV1_xxx’cr’
BV2_xxx’cr’
BV3_xxx’cr’
+9.75V_xxx’cr’
-5V_xxx’cr’
PROG_xxx’cr’
SFLT_#’cr’’lf’]
RF Output (ON/OFF) Actual Status
HPA Converter Module (OK/FLT)
Bias Voltage #1 (OK/FLT)
Bias Voltage #2 (OK/FLT)
Bias Voltage #3 (OK/FLT)
+9.75 V Power Supply (OK/FLT)
–5 Volt Power Supply (OK/FLT)
Inter-processor Communications (OK/FLT)
Number of stored faults (# = 1 to 10)
HP Current
Faults
16 Watt SSPAs
Current Faults
(Comtech EF
Data)
Command
Response
<add/HS_’cr’
>add/HS_’cr’
RF_xxx’cr’
HPA_xxx’cr’
BV1_xxx’cr’
BV2_xxx’cr’
BV3_xxx’cr’
BV4_xxx’cr’
BV5_xxx’cr’
+9.75V_xxx’cr’
-5V_xxx’cr’
PROG_xxx’cr’
SFLT_#’cr’’lf’]
RF Output (ON/OFF) Actual Status
HPA Converter Module (OK/FLT)
Bias Voltage #1 (OK/FLT)
Bias Voltage #2 (OK/FLT)
Bias Voltage #3 (OK/FLT)
Bias Voltage #4 (OK/FLT)
Bias Voltage #5 (OK/FLT)
+9.75 V Power Supply (OK/FLT)
–5 Volt Power Supply (OK/FLT)
Inter-processor Communications (OK/FLT)
Number of stored faults (# = 1 to 10)
Page view 118