Remote Control Operation SDM-100A Satellite Modem
A–28 Rev. 0
A.5 Stored Faults
Information on stored faults is returned when requested. If no stored fault exists for a given fault number,
the words “NO Fault” will be returned instead of the normal time/date status information.
The following symbols are commonly used to define the stored faults status commands:
• # Fault number (0 to 9). “0” is the first fault stored.
• hh Hours in 24-hr. format.
• mm Minutes.
• ss Seconds.
• MM Month.
• DD Day.
• YY Year.
Modulator
Stored
Faults
Command:
Response:
<add/MSF_#'cr'
>add/MSF_# hh:mm:ss MM/DD/YY'cr'
MOD_xxx'cr'
SYN_xxx'cr'
DCS_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
AGC_xxx'cr''lf']
Module (OK/FLT)
IF Synthesizer (OK/FLT)
Data Clock Synthesizer (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
AGC Level (OK/FLT)
Demodulato
r Stored
Faults
Command:
Response:
<add/DSF_#'cr'
>add/DSF_# hh:mm:ss MM/DD/YY'cr'
MOD_xxx'cr'
CD_xxx'cr'
SYN_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
DSCR_xxx'cr'
BERT_xxx'cr''lf']
Demod Module (OK/FLT)
Carrier Detect (OK/FLT)
IF Synthesizer Lock (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
Descrambler (OK/FLT)
BER Threshold (OK/FLT)
Interface
Transmit
Side Stored
Faults
Command:
Response:
<add/ITSF_#'cr'
>add/ITSF_# hh:mm:ss MM/DD/YY'cr'
CLK_xxx'cr''lf']
TAC_xxx'cr' (See Note)
Selected Transmit Clock Activity (OK/FLT)
Transmit Audio Clip (OK/FLT)
Note: Status only returned when ADPCM board is installed.
Interface
Receive
Side Stored
Faults
Command:
Response:
<add/IRSF_#'cr'
>add/IRSF_# hh:mm:ss MM/DD/YY'cr'
CLK_xxx'cr'
UNFL_xxx'cr'
OVFL_xxx'cr''lf']
RAC_xxx'cr' (See Note)
DMXL_xxx'cr' (See Note)
HOOK_xxx'cr' (See Note)
Selected Buffer Clock Activity (OK/FLT)
Buffer Underflow (OK/FLT)
Buffer Overflow (OK/FLT)
Receive Audio Clip (OK/FLT)
Demultiplexer Lock (OK/FLT)
Remote Off Hook Fault (OK/FLT)
Note: Status only returned when ADPCM board is installed.
Common
Equipment
Stored
Faults
Command:
Response:
<add/CSF_#'cr'
>add/CSF_# hh:mm:ss MM/DD/YY'cr'
M&C_xxx'cr'
INT_xxx'cr'
BAT_xxx'cr'
+5_xxx'cr'
+12_xxx'cr'
-12_xxx'cr''lf']
Monitor & Control Module (OK/FLT)
Data Interface Module (OK/FLT)
Battery/Clock (OK/FLT)
+5V Power Supply (OK/FLT)
+12V Power Supply (OK/FLT)
-12V Power Supply (OK/FLT)
Page view 179
1 2 ... 175 176 177 178 179 180 181 182 183 184 185 ... 211 212

Comments to this Manuals

No comments

Novatel Navigators user manuals

The list of Novatel Navigators products contains 1 user manuals for 1 models. All pdf user’s guides are available for download or viewing online.

Click on an alphabet below to scroll to the full list of models starting with that letter

Models Document Type
GNSS Receiver and Antenna SMART-AG
User Manual   Novatel GNSS Receiver and Antenna SMART-AG User's Manual [en] , 76 pages