SMS-758 Modem Protection Switch Remote Control Operation
MN/SMS758 Rev. 3 B–13
B.3.5.3 Mode Command
The Mode command directs the SMS-758 to enter the specified mode.
Command:
<add/MODE_yyyyyy”cr”
Response:
>add/MODE_yyyyyy”cr”
Status Only:
<add/MODE_”cr”
Response:
>add/MODE_yyyyyy”cr””lf”]
Where: yyyyyy = REMOTE, LOCAL, AUTO, or BYPASS.
B.3.5.4 Set Backup Modulator Online/Offline
The modulator online command puts the specified backup modulator online for the
specified prime modulator.
Note: If “0” is used as the prime modulator argument “x”, the specified backup
modulator is offline or will be taken offline.
Command:
<add/MOL_By_x”cr”
Response:
>add/MOL_By_x”cr””lf”]
Status Only:
<add/MOL_By”cr”
Response:
>add/MOL_By_x”cr””lf]
Where:
y = 1 or 2 (backup modulator number).
x = 0 to 8 (prime modulator number).
B.3.5.5 Set Backup Demodulator Online/Offline
The demodulator online command puts the specified backup demodulator online for the
specified prime demodulator.
Note: If “0” is used as the prime demodulator argument “x”, the specified backup
demodulator is offline or will be taken offline.
Command:
<add/DOL_By_x”cr”
Response:
>add/DOL_By_x”cr””lf”]
Status Only:
<add/DOL_By”cr”
Response:
>add/DOL_By_x”cr””lf”]
Where:
y = 1 or 2 (backup demodulator number).
x = 0 to 8 (prime demodulator number).