OMS11 1:1 Redundancy Switch Appendix B
TM133 – Rev. 1.1 B-9
<1> Switch Delay Demod NoFault LSB
Opcode <2087h> Query OMS11 Switch Alarms
Query Response Data Field (5 bytes):
<1> Global Current Alarm Bit 0: 1 = Global Alarm
Bit 1:.7: unused, return 0
<1> External Current Alarms
Bit 0: 1 = Mod A Alarm
Bit 1: 1 = Force Mod A Alarm
Bit 2: 1 = Demod A Alarm
Bit 3: 1 = Force Demod A Alarm
Bit 4: 1 = Mod B Alarm
Bit 5: 1 = Force Mod B Alarm
Bit 6: 1 = Demod B Alarm
Bit 7: 1 = Force Demod B Alarm
<1> Switch Current Alarms
Bit 0: 1 = Switch Power 1 Alarm
Bit 1: 1 = Switch Power 2 Alarm
Bit 2: 1 = Switch Firmware Alarm
Bit 3: 1 = Switch NV Alarm
Bit 4: 1 = Switch Internal Alarm
Bit 5:.7: unused, return 0
<2> Spare Current Alarms Always 0
Opcode: <2089h> Query OMS11 Switch Alarms Mask
Query Response Data Field (4 Bytes):
<1> External Alarm Masks 1 = Enabled, 0 = Masked Off
Bit 0: 1 = Mod A Alarm Enabled
Bit 1: 1 = Force Mod A Alarm Enabled
Bit 2: 1 = Demod A Alarm Enabled
Bit 3: 1 = Force Demod A Alarm Enabled
Bit 4: 1 = Mod B Alarm Enabled
Bit 5: 1 = Force Mod B Alarm Enabled
Bit 6: 1 = Demod B Alarm Enabled
Bit 7: 1 = Force Demod B Alarm Enabled
<1> Switch Alarm Masks 1 = Enabled, 0 = Masked Off
Bit 0: 1 = Switch Power 1 Alarm Enabled
Bit 1: 1 = Switch Power 2 Alarm Enabled
Bit 2: 1 = Switch Firmware Error Enabled
Bit 3: 1 = Switch NV Alarm
Bit 4: 1 = Switch Internal Alarm Enabled
Bit 5:.7: unused, return 0
<2> Spare Current Alarms Always 0
Opcode: <2289h> Command OMS11 Switch Alarms Masks
Command Data Field (4 Bytes):
<1> External Alarm Masks 1 = Enabled, 0 = Masked Off
Bit 0: 1 = Mod A Alarm Enabled
Bit 1: 1 = Force Mod A Alarm Enabled
Bit 2: 1 = Demod A Alarm Enabled